Evaluation of urine dipsticks for quality control of residual erythrocytes and leukocytes in leukocyte-depleted donor plasma
Currently used methodologies for quality control of residual leukocytes and erythrocytes in leukocyte-depleted plasma are either expensive or time-consuming. It has been proposed that urine dipsticks could be used as a screening method for residual erythrocytes. The aim was, therefore, to evaluate if urine dipsticks could be used to detect residual erythrocytes and also residual leukocytes in leuk